PELT®
(Pulse/Echo Layer Thickness) products from JSR Ultrasonics are microprocessor
based ultrasonic thickness measurement systems.
PELT Gauges
are internationally recognized for direct and precise multi-layer
gauging of coatings on both non-metallic and metallic substrates.
PELT Gauges are non-destructive contact gauging systems that do
not damage the coating or destroy the sample being measured.
Single layer coatings as well as multi-layered coatings can be made
with the PELT Gauge. With one measurement, the PELT Gauge can accurately
measure the thickness of each individual layer of a coating (up
to 5 layers). This is true even if the layers were applied
“wet on wet”, as is the case with many basecoat/clearcoat systems
in use today.
Since
the measurements are made on finished parts, there is no need to
waste resources preparing special samples for measurement. Measurements
can be made on virtually any type of substrate. Corrosion inhibitors
and pre-treated metallic substrates (i.e. galvanization) pose no
problem. There is no need to subtract the thickness of the inhibitors
or treatments from the measurement (a common practice with conventional
thickness gauges).
On plastic
or composite substrates, the PELT Gauge measures each layer down
to the substrate. Varying substrate thickness or laminated substrates
do not affect the ability to gauge or the accuracy of the layer
thickness measurements.
With
optional probes, the PELT can be configured to measure many different
materials and in some cases, substrate thickness itself can be measured.
|